@@ -521,10 +521,10 @@ Configuration File '[program:x]' Section Settings
|
|
|
are defined by the combination of the 'numprocs and 'process_name'
|
|
|
parameters in the configuration. By default, if numprocs and
|
|
|
process_name are left unchanged from their defaults, the group
|
|
|
- represented by '[program:x]' will hae a single process named 'x' in
|
|
|
- it. This provides a modicum of backwards compatibility with older
|
|
|
- supervisor releases, which did not treat program sections as
|
|
|
- homogeneous process group defnitions.
|
|
|
+ represented by '[program:x]' will be named 'x' and will have a
|
|
|
+ single process named 'x' in it. This provides a modicum of
|
|
|
+ backwards compatibility with older supervisor releases, which did
|
|
|
+ not treat program sections as homogeneous process group defnitions.
|
|
|
|
|
|
But for instance, if you have a '[program:foo]' section with a
|
|
|
'numprocs' of 3 and a 'process_name' expression of
|
|
@@ -567,7 +567,7 @@ Configuration File '[eventlistener:x]' Section Settings (New in 3.0)
|
|
|
Supervisor allows specialized homogeneous process groups ("event
|
|
|
listener pools") to be defined within the configuration file. These
|
|
|
pools contain processes that are meant to receive and respond to
|
|
|
- event notifications from supervisor's event system. Eee "Supervisor
|
|
|
+ event notifications from supervisor's event system. See "Supervisor
|
|
|
Events" elsewhere in this document for an explanation of how events
|
|
|
work and how to implement event listener programs.
|
|
|
|
|
@@ -1190,7 +1190,32 @@ Event Listener Error Conditions
|
|
|
|
|
|
Capture Mode and Process Communication Events (New in 3.0)
|
|
|
|
|
|
- XXX TODO
|
|
|
+ If a '[program:x]' section in the configuration file defines a
|
|
|
+ "stdout_capturefile" or "stderr_capturefile" parameter, each process
|
|
|
+ represented by the program section may emit special tokens on its
|
|
|
+ stdout or stderr stream (respectively) which will effectively cause
|
|
|
+ supervisor to emit a "PROCESS_COMMUNICATION" event type.
|
|
|
+
|
|
|
+ The process communications protocol relies on two tags, one which
|
|
|
+ commands supervisor to enter "capture mode" for the stream and one
|
|
|
+ which commands it to exit. When a process stream enters "capture
|
|
|
+ mode", data sent to the stream will be sent to a separate logfile
|
|
|
+ (the "capturefile"). When a process stream exits capture mode, the
|
|
|
+ data in the capturefile is read into memory (a maximum of 2MB), and
|
|
|
+ a PROCESS_COMMUNICATION event is emitted by supervisor, which may be
|
|
|
+ intercepted by event listeners.
|
|
|
+
|
|
|
+ The tag to begin "capture mode" in a process stream is
|
|
|
+ '<!--XSUPERVISOR:BEGIN-->'. The tag to exit capture mode is
|
|
|
+ '<!--XSUPERVISOR:END-->'. The data between these tags may be
|
|
|
+ arbitrary, and forms the payload of the PROCESS_COMMUNICATION event.
|
|
|
+ For example, if a program is set up with a stdout_capturefile, and
|
|
|
+ it emits the following on its stdout stream::
|
|
|
+
|
|
|
+ <!--XSUPERVISOR:BEGIN-->Hello!<!--XSUPERVISOR:END-->
|
|
|
+
|
|
|
+ .. supervisor will emit a PROCESS_COMMUNICATIONS_STDOUT event with
|
|
|
+ data in the payload of "Hello!".
|
|
|
|
|
|
Signals
|
|
|
|